Installing and configuring the QLogic QLA4010 iSCSI HBA (TOE)
81
Miscellaneous Planning and Procedures
From the HBA Options, you can set the iSCSI HBA parameters
including IP address, subnet mask, and gateway. If an iSNS
server is being used for your iSCSI configuration follow the
procedure for setting up iSNS later in “Configuring iSNS settings
for QLA4010”, next.
Figure 55 SANsurfer iSCSI HBA manager, HBA options
Configuring iSNS settings for QLA4010
For iSNS support, the QLA4010 must be running the correct driver.
Refer to the EMC Support Matrix for latest version.
Targets must register with the iSNS server. To register, enable the
iSNS server and enter the IP address using the SANsurfer iSCSI
HBA Manager, HBA Options, Network, Enable iSNS dialog box.
Click Save HBA under the Network tab on the SANsurfer iSCSI
HBA Manager, HBA Options tab.