Special instructions for the EMC CLARiiON CX-200-series
109
Miscellaneous Planning and Procedures
Direct-connect dual-host clustering configurations
For CLARiiON CX200-Series direct-connect dual-host cluster
configurations only with QLA234x HBAs, you must follow all
procedures described in this section.
Check for an updated
HBA driver
For CLARiiON CX200-Series direct-connect dual-host cluster
configurations with only QLA234x HBAs, you may need a separate
driver and firmware download. The EMC Support Matrix notes
whether separate driver and firmware files are required.
For each HBA determined to require updated firmware and drivers,
follow the instructions on “Downloading latest QLogic
drivers/firmware/BIOS files” on page 16. Be sure to reference the
Name and Description fields to select the correct CX200-Series
direct-connect dual-host cluster-compatible files.
Reconfigure the HBA
jumper
For CLARiiON CX200-Series direct-connect dual-host cluster
configurations with only QLA234x HBAs, you must change the
default HBA optic jumper position:
CAUTION
Modifying the jumper setting without using the recommended
firmware/drivers can cause the HBA to lose connectivity.
1. Remove the HBA from the server as instructed by your server
guide.
2. Locate jumper(s) J3 (QLA2340) or J3 and J4 (QLA2342), shown in
Figure 64 on page 110.