EMC Fibre Channel and iSCSI with QLogic Host Bus Adapters in the Windows Environment
Installation and Configuration
Figure 27 Driver handle numbers
11. Find the driver handle numbers that correspond to those listed
for the QLogic HBAs (as shown in Figure 27). Note the two digits
(proceeded by Ctrl, as shown in Figure 27) next to the driver
handles for the QLogic HBAs. These are control handles.
12. Determine the HBA instance that will be used for boot, and enter
the QLogic Fibre Channel Driver Configuration Utility by
typing drvcfg -s <driver handle> <control handle> (where
driver handle and control handle are the values that correspond
to the HBA instance to be used for boot. In this example, "
drvcfg
-s 5f 62
" is used.)
13. Press Enter.
The Fibre Channel Driver Configuration Utiliity menu will be
displayed (as shown in Figure 28 on page 45).