Emc QLogic Manuel d'utilisateur Page 72

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 104
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 71
3
3-36
EMC Fibre Channel with QLogic HBAs in the Windows Environment
Configuring an EMC Boot Device
Replacing a Boot HBA
If a boot HBA fails, you can replace it with a new one as described in
this section.
EMC Symmetrix
Follow the procedure under Configuring a Symmetrix Boot Device.
EMC CLARiiON
Shut down and power off the server.
Replace the HBA in the identical location and reconnect cabling.
(Fabric configuration only) Repeat the procedure under Preparing
the Fabric on page 3-19, and replace the old HBA’s WWPN with
the new HBA’s WWPN.
Repeat the procedure under Verifying HBA Driver and Digital
Signature Installation on page 3-28.
QLogic_Windows.book Page 36 Thursday, March 10, 2005 10:31 AM